Critical equipment monitoring

The alarm someone
sees in time.

DROME sensors on cold rooms, freezers, MRI suites, medical air, water tanks and generators. Alerts reach the app, WhatsApp, SMS, voice call and email before a reading leaves its range, with a record of who saw it and what they did.

30–60 min
head start on trend alerts from DROME Predict
16
measurements on one dashboard, from temperature to power loss
No retrofit
the sensor fits equipment from any manufacturer
Integrates with

Running at hospitals, labs and manufacturers like these

DF Star · Rede D'OrHospital da Bahia · DASASENAI CIMATECHemobrásHospital São RafaelHUFSCarFujifilmGlobal FarmaPVAXCoca-ColaSyngentaLATAMABBInventusPiknPakDF Star · Rede D'OrHospital da Bahia · DASASENAI CIMATECHemobrásHospital São RafaelHUFSCarFujifilmGlobal FarmaPVAXCoca-ColaSyngentaLATAMABBInventusPiknPak
THE PROBLEM

Many losses start outside the equipment.

A power cut, a door left open, an alarm nobody sees.

54.9%
of vaccine losses in Ceará, Brazil, came from power outages, not the fridge
Epidemiol. Serv. Saúde, 2020 · 2014–16 data
160,767
doses of vaccines and sera lost in Ceará over three years (BRL 1.83M)
Epidemiol. Serv. Saúde, 2020
$80K+
to repair an MRI quench, plus $10–15K for each day it is down
ECRI
USD 34.1B
lost to cold-chain failures every year
Supply Chain Dive / CDC

Failure without warning

Equipment drifts out of range overnight or on a weekend. The first sign is the material already lost.

Alarms that don't become action

The siren goes off in an empty room or the email lands in spam. Nobody knows who saw it or what was done.

Audits on spreadsheets

When the inspection arrives, the record still depends on spreadsheets, pens and goodwill.

What changes with DROME

Temperature, humidity, pressure, level, current, power loss, door open and vibration feed the same dashboard, among the 16 measurements DROME tracks. The AI cross-checks the readings and answers each of those failures.

A warning from the trend, before it leaves range.

For failures without warning. DROME Predict tracks each sensor's curve and warns while there is still time to move the material or call maintenance, overnight and on weekends too.

How DROME Predict forecasts
DROME dashboard chart with Cold Room 02 temperature rising and the DROME Predict trend: 12 °C in about 15 minutesDROME PREDICTTrend if nothing is done12 °C in ~15 min

The whole team alerted, and you know who saw it.

For alarms that don't become action. The alert reaches the app, WhatsApp, SMS, voice call and email of everyone subscribed at the same time. If nobody acknowledges, it escalates to the next person, all the way to a phone call. The event shows who received it, on which channel, who read it and the note from whoever acted.

DROME dashboard event with the recorded justification and the notification list: user, channel, status and views

At inspection time, the record is already there.

For audits on spreadsheets. Readings, alarms, notes and every user action go into the audit log, with cryptographic integrity. Reports for RDC 430, ONA and JCI come from those records.

See supported standards
DROME dashboard audit log with user, action, date and status for each entry
How it works

From alarm to recorded action.

Real screens from the DROME web dashboard and app: the alarm, the trend, the likely cause flagged by AI, who was notified, what was done and the audit record.

WHAT DROME MONITORS

Freezers, gases, power and rooms on one dashboard.

16 measurements, from temperature and humidity to power loss, open doors and vibration. Start with the cold chain and add the rest with the same app and the same contract.

app.drome.com.brLIVE
DROME platform monitoring panel, with systems and sensors in real time
Live monitoringAlarm bands and complianceReports and audit
Explore the technology

Pick a piece of equipment

See what DROME measures on it, the alert that reaches the phone and what is at stake.

Cold room and vaccine fridge

What DROME measures
Temperature and humidity, door left open and power loss.
Sample alert
DROME · nowCold Room 02 · Pharmacy8.62 °C · above the 8 °C limit
What is at stake
Batches of vaccines and temperature-sensitive drugs. In Ceará, Brazil, 160,767 lost doses added up to R$ 1.83 million in three years.Epidemiol. Serv. Saúde, 2020
See the Cold Chain & Environments module
NEXT STEP

Want to see it on equipment like yours? The demo takes 30 minutes.

DROME PREDICT

Your cold room
will breach in 40 minutes.

It used to be an alarm. Now it's a prediction. The model learns each unit's pattern and warns while there's still time to act.

01
Peak detection
Identifies statistically anomalous readings.
from day 1
02
Drift detection
Gradual patterns before the breach.
~30 readings/sensor
03
Breach prediction
30–60 min of advance notice.
after ~30 days of readings

Technology already running with our customers. Prerequisite: 30 days of sensor readings for model personalization.

SENSOR · CF-11 · LIVE
Cold room, Central Pharmacy · Block A
6.0°C
DRIFT +0.4°F/min (+0.22°C/min)
Measured temperatureAI predictionUncertainty band ±σANVISA limit
OUR OWN HARDWARE

Sensor and gateway designed and built by DROME

The sensor measures at the equipment and sends over LoRa to the gateway. If the internet drops, the gateway stores the readings; if the power fails, it keeps running on battery.

DROME Satellite Sensor, wireless measurement device
Satellite SensorMeasures at the equipment, wireless
DROME Data Gateway, with two antennas
Data GatewayAggregates the sector and sends to the cloud
Explore the hardware
CUSTOMERS

What changed after a year with DROME.

“After a year with the system, our routine changed completely. We gained predictability where before we could only react.”
HB
Hospital da Bahia, DASA
“The system is fully efficient. It has never let us down.”
World Medicamentos
WHY DROME?

One vendor, from sensor to support.

Hardware, platform, calibration and support under one contract. Our own sensor and gateway, a cloud with end-to-end encryption and integration with your HIS.

The sensor battery lasts 1 to 5 years. If the internet drops, the gateway stores the readings; if the power fails, it runs on its own battery. Records carry cryptographic integrity for audits, and 24/7 support comes with a contractual SLA.

P1 in 2 h
Critical incident resolution, per the contract SLA
LGPD
End-to-end encrypted data
HIS
Integrates with MV, Tasy, Smart Pixeon and open systems
ISO 9001
Certified operations
ANVISA + FDA
Supports RDC 430 and 21 CFR Part 11 compliance
24/7
Support with a contractual SLA
FAQ

Frequently asked questions

The essentials about the platform, the hardware and the pricing model.

DROME monitors critical equipment for hospitals, labs, biobanks and pharmaceutical distributors: freezers, cold rooms, vaccine fridges, medical gases and the power that keeps them running. Our own sensors cover 16 measurements; the platform warns before a reading leaves its range and records who was notified and what was done.

See DROME running in a setting like yours.

In 30 minutes, a specialist walks you through the dashboard, an alert arriving on the phone and the audit report, with data from an environment like yours. Hardware on loan, no CAPEX.

Email contato@drome.io