Energy waste
visible in
real time.
Continuous monitoring of electrical consumption, power quality, water leaks and flow per circuit. Spot waste before the bill arrives and detect failures before the blackout.
Hospitals waste 20–30% of energy for lack of visibility.
Air conditioning running in an empty room, a water leak in the basement, a chiller consuming 40% above pattern. Without per-circuit metering, waste is invisible until the bill arrives.
Our energy bill was a number at the end of the month. We had no idea which wing consumed the most, which equipment had a problem, nothing. With DROME we identified a chiller consuming 40% above normal in 3 days.
Meter → gateway → dashboard, without stopping the hospital.
Current sensors installed in the existing switchboards without shutting down the circuit. Non-invasive ultrasonic flow sensors on the pipes.
Sensors on the switchboards
Current CTs clamped onto existing breakers without shutting down the circuit. Measurement of kWh, power factor, harmonics and voltage every minute.
Water flow
Clamp-on ultrasonic sensors installed externally on the pipes. They detect water flow, pressure and temperature at critical points.
Automatic baseline
The AI learns the consumption pattern of each circuit by hour, day of the week and seasonality. It alerts when real consumption deviates more than 10% from expected.
ISO 50001 reports
Consumption dashboards by wing, circuit and equipment. Energy efficiency reports for accreditation and RFQ audits.
Energy and water: total visibility, action before the crisis.
Energy anomaly AI
Detects anomalous consumption patterns before they cause a failure. A chiller heating up before it locks appears as an anomaly weeks before the shutdown.
- Baseline per equipment and time
- Progressive degradation alert
- Failure prediction on critical equipment
Power quality
Monitoring of harmonics, voltage sag/swell, dips and transients that damage high-cost electromedical equipment.
- THD-V and THD-I harmonics
- Sag/swell and flicker
- ANEEL quality report
Water management
Non-invasive ultrasonic sensors detect leaks, measuring flow at critical points without interrupting supply.
- Leak detection ±1%
- Water balance per sector
- Abnormal night-consumption alert
Non-invasive installation
Current CTs installed with the circuit energized. Clamp-on flow sensors without cutting the pipe. Zero downtime.
- Split-core CT, no shutdown
- Clamp-on ultrasonic for water
- No civil works
BMS and SCADA integration
Connects with existing BMS (BACnet, Modbus) and SCADA systems. Imports data from smart meters already installed.
- Native BACnet/IP
- Modbus TCP/RTU
- MQTT for SCADA
ISO 50001 reports
Generate energy management plans, energy performance indicators (EnPI) and energy review reports for certification.
- EnPI per sector and equipment
- Baseline analysis
- Efficiency target plan
Energy efficiency as a regulatory requirement.
ISO 50001, PROCEL Hospitais and sustainability certifications require continuous monitoring and reports. DROME delivers this automatically, with no manual work.
Questions about energy and water monitoring.
Questions about installation or compatibility? Talk to a specialist.
Ready to see Energy & Water in action?
Book a demo with our team and see live predictions in your own environment.